Module 5 Set-2

ALL THE BEST

 

Results

YOU HAVE PASSED THIS TEST..

 

Will you do a favour for me by clicking on any ads…

PRACTICE AGAIN..

 

Will you do a favour for me by clicking on any ads…

#1. Electromagnetic compatibility is achieved by:

#2. The DAC used in a successive approximation ADC is usually:

#3. The Q output of an R-S bistable is at logic 0.This means that the bistable is:

#4. Which computer bus is used to specify memory locations:

#5. Light propagates in a fibre optic by means of:




#6. Which aircraft standard applies to fibre-optic networks:

#7. Weather radar is an example of:

#8. The horizontal situation indicator (HSI) uses information derived from:

#9. The two sets of flight regulations that a pilot may fly by are:

#10. An ARINC 629 data bus cable uses:




#11. . The upper ECAM display provides:

#12. The cone of acceptance of an optical fibre and a light source is measured between:

#13. On an EHSI in weather radar mode, a severe storm would be shown as:

#14. The maximum data rate supported by the FDDI bus is:

#15. A group of bits transmitted at the same time is referred to as:




#16. A DAC can produce 256 different output voltages. This DAC has a resolution of:

#17. A bus arbitration system based on the physical location of cards is referred to as:

#18. The decimal number 37 is equivalent to the binary coded decimal (BCD) number:

#19. The normal supply voltage for a TTL logic device is:

#20. The validity of an ARINC 429 data word is checked by using:




#21. The human eye is most sensitive to:

#22. The method of data encoding used in an ARINC 429 bus is known as:

#23. Where is the ‘rising runway’:

#24. A level-C software classification is one in which a failure could result in:

#25. To create a bidirectional communications link within an ARINC 429 system:




#26. In a basic ‘T’ configuration of instruments:

#27. A significant advantage of fibre-optic networks in modern passenger aircraft is:

#28. When expressed in hexadecimal an octal value of 54 is the same as:

#29. . Typical displays on an EHSI are:

#30. A NAND gate with its output inverted has the same logical function as:




#31. When compared with an LCD, a CRT display offers the advantage that:

#32. In a bipolar ADC a logic 1 in the MSB position indicates:

#33. The voltages present on an ARINC 429 data bus cable are:

#34. A particular problem with the build-up of static charge is that:

#35. Adjacent blue and red phosphors are illuminated on the screen of a colour CRT. The resulting colour produced will be:




#36. Data is converted from serial to parallel and parallel to serial by means of:

#37. In order to represent negative data values, BNR data uses:

#38. A semiconductor memory consists of 256 rows and 256 columns. The capacity of this memory will be:

#39. Operational faults in FMS can be detected by:

#40. The pins on a DIL packaged integrated circuit are numbered:




Previous
Finish

Leave a Comment